AGA and Range Cooker Removal

AGA and Range Cooker Removal

Reconditioning Assessment and Cast-Iron Recycling

Advice on whether your old cooker could be reconditioned and resold, and responsible recycling of cast iron, steel and enamel when it cannot.

Free AGA and Range Cooker Removal quote

No obligation. We only use your details to reply about this job.

Reconditioning Assessment and Cast-Iron Recycling — AGA and Range Cooker Removal

What's involved

Not every old AGA or Rayburn is scrap. Cast-iron heat-storage cookers have an established reconditioning trade, where castings are cleaned, enamel is assessed or re-enamelled, and the cooker is converted to a different fuel and resold. Whether yours has value depends on the model, its age, the condition of the enamel and hotplates, and whether all the parts are present. Chipped, crazed or rusted enamel and cracked castings reduce value sharply. Send clear photos of the top, front, doors and data badge with your quote request and we will tell you honestly whether reconditioning is realistic. Where it is, the removal price may be lower. Where it is not, the cast iron goes to a metal recycler, and the enamel panels, insulation, firebricks and electrical parts are separated for appropriate treatment. You receive a waste transfer note covering everything taken away.

How we handle it

  1. Send details and photos

    Tell us the make, model, number of ovens, fuel type and whether it heats water or radiators. Photos of the cooker, its data badge, the flue and the route out let us plan and price accurately.

  2. Fixed quote and plan

    We confirm a single fixed price, the number of crew, how long the job should take, and which engineer is needed to disconnect the fuel supply. If the cooker may contain asbestos, we recommend testing first.

  3. Disconnection and cooling

    The cooker is switched off at least 24 hours before so the castings are cold. A Gas Safe, OFTEC or electrical engineer isolates and caps the supply, and any boiler circuit is drained.

  4. Dismantling and removal

    The team protects floors, strips the cooker into sections, vacuums insulation, and carries the castings out. A typical two-oven AGA takes three to five hours from start to clean-up.

  5. Clean-up and recycling

    The alcove is swept and vacuumed and the flue covered. Cast iron is recycled or sent for reconditioning, and you receive a waste transfer note for everything removed.

Price guide

AGA and range cooker removal is priced on the cooker's size and weight, how much dismantling it needs, the fuel type and the access. A modern range cooker is a short job. A four-oven cast-iron AGA with a boiler and an awkward route can take most of a day. Reconditionable cookers may lower the price.

  • Rayburn or Stanley with boiler: £350–£600. Heating system must be drained and capped by a plumber before work starts.
  • Three or four-oven AGA: £450–£750. Longer dismantle and more castings to carry; route and access affect price.
  • Two-oven AGA dismantle and removal: £350–£550. Full on-site strip-down, insulation removal, clean-up and cast-iron recycling.

Questions about reconditioning assessment and cast-iron recycling

What do I do if my Rayburn heats my radiators?

If your Rayburn or Stanley has a boiler, a plumber or heating engineer must drain the heating system and cap the flow and return pipes before removal. You will need another source of heating and hot water ready, or arranged soon after. We can coordinate timing with your heating engineer to keep the gap as short as possible.

Can an AGA be removed in one piece?

Almost never. An assembled AGA is too heavy and too wide for most doorways, and moving it whole risks floor damage and injury. It was built on site from sections and has to come out the same way. Dismantling also allows the insulation to be removed and bagged properly before the castings are carried out.

What happens to the flue when an AGA is removed?

The flue pipe and any register plate are taken down as part of the removal, and the opening into the chimney or wall is temporarily covered. If you plan to install a new range cooker or wood burner, your installer must check whether the existing flue or chimney is suitable for the new appliance before connecting it.

Get a free aga and range cooker removal quote

Tell us what you need and we'll come back with a clear price.

Request a quote